================ IRIS/RDA patch 1 =============== IrisToOdimHdf5 The output file name generated by IrisToOdimHdf5 had different naming schema for RAW and secondary products. Time stamps in the output file names were badly formated. Additionally, the "prodpar" attribute of the Cartesian products was not set correctly. IrisToOdimHdf5-9.0.0.1.gz --- posted 28-April-2018 Installation instructions: # cp IrisToOdimHdf5-*.gz /usr/sigmet/config/pipes # cd /usr/sigmet/config/pipes # mv IrisToOdimHdf5 IrisToOdimHdf5-9.0.0 # gunzip IrisToOdimHdf5-*.gz # chown operator.users IrisToOdimHdf5-9.0.0.1 # chmod 775 IrisToOdimHdf5-9.0.0.1 # ln -s IrisToOdimHdf5-9.0.0.1 IrisToOdimHdf5 ================ IRIS/RDA patch 2 ================== IRIS Antenna to Network Manager Interface Fixed the lat/long decimal points, and adding the radar model property. Read README.md for more details ant2nmpatch-install.bsx --- posted 21-December-2018 Installation instructions: 1) Become root user 2) run ant2nmpatch-install.bsx 3) double check the /usr/sigmet/config/ant2inm.ini to make sure that hostname and authentication keys did not change. Only [RADAR_INFO] section is adding to. ================ IRIS/RDA patch 3 ================== socket server (sserver) patch to fix wrong UTC time when request from IRIS Focus if data is recording in local time from the IRIS. sserver-patch-install.bsx --- posted 15-February-2019 Installation instructions: 1) Become root user, and stop IRIS 2) run sserver-patch-install.bsx 3) Check if the patch install correctly by running ls -l /usr/sigmet/bin/sserv*, the output should look like: lrwxrwxrwx. 1 operator users 31 Feb 15 16:59 /usr/sigmet/bin/sserver -> /usr/sigmet/bin/sserver-9.0.0.3 -rwxrwxr-x. 1 operator users 1536848 Feb 15 16:57 /usr/sigmet/bin/sserver-9.0.0 -rwxrwxr-x. 1 operator users 1845976 Feb 15 09:02 /usr/sigmet/bin/sserver-9.0.0.3 ================ IRIS/RDA patch 4 ================== socket server (sserver) patch to fix problem when there is a bad product generated then the IRIS Focus server cannot establish connection with IRIS Analysis server. For example, if RAIN1 product were configured with 3D CAPPI then it created a bad RAIN1 product. sserver-patch2-install.bsx --- posted 19-April-2019 Installation instructions: 1) Become root user, and stop IRIS 2) run sserver-patch2-install.bsx 3) Check if the patch install correctly by running ls -l /usr/sigmet/bin/sserv*, the output should look like: lrwxrwxrwx. 1 operator users 31 Apr 19 13:56 /usr/sigmet/bin/sserver -> /usr/sigmet/bin/sserver-9.0.0.4 -rwxrwxr-x. 1 root users 1536848 Apr 19 13:53 /usr/sigmet/bin/sserver-9.0.0 -rwxrwxr-x. 1 operator users 9096238 Apr 19 13:01 /usr/sigmet/bin/sserver-9.0.0.4 If you have patch2 installed then it should display like: lrwxrwxrwx. 1 operator users 31 Apr 19 13:46 /usr/sigmet/bin/sserver -> /usr/sigmet/bin/sserver-9.0.0.4 -rwxrwxr-x. 1 root users 9096238 Apr 19 13:33 /usr/sigmet/bin/sserver-9.0.0 -rwxrwxr-x. 1 operator users 1845976 Feb 15 14:02 /usr/sigmet/bin/sserver-9.0.0.3 -rwxrwxr-x. 1 operator users 9096238 Apr 19 13:01 /usr/sigmet/bin/sserver-9.0.0.4 ================ IRIS/RDA patch 5 ================== At some point the resolution of the FCAST product was fixed and an option to chenge it was removed from the product configuration. That change has to be reverted. fcast_pcf-9.0.0.5.tgz Installation instructions: 1) Become root user, and stop IRIS 2) # cp fcast_pcf-*.tgz /usr/sigmet/bin # cd /usr/sigmet/bin # mv iris iris-9.0.0 # mv server server-9.0.0 # tar xzf fcast_pcf-*.tgz # chown operator.users iris-9.0.0.5 server-9.0.0.5 # chown root.users server-9.0.0.5 # chmod 775 iris-9.0.0.5 server-9.0.0.5 # ln -s iris-9.0.0.5 iris # ln -s server-9.0.0.5 server # systemctl daemon-reload ================ IRIS/RDA patch 6 ================== Fixes a case where power monitoring might give a false alarm when the reflective power is jumping around the low measurement limit of the sensor. rcp8-9.0.0.6.gz --- posted 21-August-2019 Installation instructions: # cp rcp8-9.0.0.6.gz /usr/sigmet/bin # cd /usr/sigmet/bin # systemctl stop rcp8 # mv rcp8 rcp8-9.0.0 # gunzip rcp8-9.0.0.6.gz # chown root.users rcp8-9.0.0.6 # chmod 6775 rcp8-9.0.0.6 # ln -s rcp8-9.0.0.6 rcp8 # chown -h root.users rcp8 # systemctl start rcp8 ================ IRIS/RDA patch 7 ================== Fixes QLW displaying wrong Azimuth/Range location for MAX product (Jira IRIS-1707). window-9.0.0.7.gz --- posted 30-December-2019 Installation instructions: # cp window-9.0.0.7.gz /usr/sigmet/bin # cd /usr/sigmet/bin # systemctl stop iris # mv window window-9.0.0 # gunzip window-9.0.0.7.gz # chown operator.users window-9.0.0.7 # chmod 775 window-9.0.0.7 # ln -s window-9.0.0.7 window # chown -h operator.users window # systemctl start iris =================== IRIS/RDA patch 8 ================ ----------------- Netcdf --------------- Add new feature to support NetCDF standard format for Radar data, and Lidar(Leosphere) Data. cfrnc2iris-9.0.0.8.tgz --- Posted 27-Jan-2020 Installation Instructtions: 1) Stop IRIS #systemctl stop iris 2) Create temp and extract files #mkdir -p /tmp/install_patch #cp cfrnc2iris-9.0.0.8.tgz /tmp/install_patch #cd /tmp/install_patch #tar zxvf cfrnc2iris-9.0.0.8.tgz 3) While in /tmp/install_patch/ install rpm #rpm -Uvh netcdf-cxx4-4.3.0-7.el7.x86_64.rpm 4) Install pipes and configuration file while in /tmp/isnatll_patch #install -m 775 -o operator -g users cfrnc2iris /usr/sigmet/config/pipes/ #install -m 664 -o operator -g users cfrnc2iris.conf /usr/sigmet/config/ 5) start IRIS #systemctl start iris 6) Clean-up #rm -rf /tmp/install_patch ------------- HDF5 ----------------- Fix major/minor task ID where IRIS Focus Datamanager cannot handle when receiving RAW file converting from HDF5 pipe. hdf52iris-9.0.0.8.gz --- Posted 27-Jan-2020 Installation Instrcutions: 1) Stop IRIS #systemctl stop iris 2) Install patch #gzip -d hdf52iris-9.0.0.8.gz #install -m 775 -o operator -g users hdf52iris-9.0.0.8 /usr/sigmet/config/pipes/ #cd /usr/sigmet/config/pipes Check if there is link to hdf52iris with #ls -l hdf52iris If there is link unlink it with the command #unlink hdf52iris If there is no link #mv hdf52iris hdf52iris-$(show_machine_code --version | awk '{print $3}') # ln -sf hdf52iris-9.0.0.8 hdf52iris # chown -h operator.users hdf52iris 3) Start IRIS #systemctl start iris ================ IRIS/RDA patch 9 ================== Important: ---------- this patch is deprecated. Please use patch 13 to address this problem. If Radar installed new dehydrator which is using snmp for communication, this rcp8 patch needs to install. rcp8-9.0.0.9.gz --- posted 19-August-2020 Installation instructions: # cp rcp8-9.0.0.9.gz /usr/sigmet/bin # cd /usr/sigmet/bin # systemctl stop rcp8 # mv rcp8 rcp8-9.0.0 ( or if rcp8 patch 6 installed, then unlink it with command "unlink rcp8") # gunzip rcp8-9.0.0.9.gz # chown root.users rcp8-9.0.0.9 # chmod 6775 rcp8-9.0.0.9 # ln -s rcp8-9.0.0.9 rcp8 # chown -h root.users rcp8 # systemctl start rcp8 ================ IRIS/RDA patch 10 ================== hdf52iris to handle Furuno lidar data for RHI, and PPI Sector scan hdf52ris-9.0.0.10.gz --- posted 22-Sep-2020 Installation instructions 1) Stop IRIS #systemctl stop iris 2) Install patch #gzip -d hdf52iris-9.0.0.10.gz #install -m 775 -o operator -g users hdf52iris-9.0.0.10 /usr/sigmet/config/pipes/ #cd /usr/sigmet/config/pipes Check if there is link to hdf52iris with #ls -l hdf52iris If there is link unlink it with the command #unlink hdf52iris If there is no link #mv hdf52iris hdf52iris-$(show_machine_code --version | awk '{print $3}') # ln -sf hdf52iris-9.0.0.10 hdf52iris # chown -h operator.users hdf52iris 3) Start IRIS #systemctl start iris ================== IRIS/RDA patch 11 ================= Fix product output to handle 16 bit data format for geotiff. Geotiff file will render incorrectly if product is generate with R moment which produce 16-bit dataa format. output-9.0.0.11.gz --- posted 16-Dec-2020 Installation instructions 1) Stop IRIS # systemctl stop iris 2) Install patch # cp output-9.0.0.11.gz /usr/sigmet/bin/ # cd /usr/sigmet/bin # mv output output-`show_machine_code --version | awk '{print $3}'` # gunzip output-9.0.0.11.gz # chown opeerator.users output-9.0.0.11 # chmod 775 output-9.0.0.11 # ln -s output-9.0.0.11 output # chown -h operator.users output 3) Start IRIS # systemctl start iris # ================ IRIS/RDA patch 12 ================== Important: --------- This patch is deprecated. Please use patch 13 to address this problem. A fault in the new Cibred dehydrator does not stop transmitter radiation. The alarm (e.g. low pressure) is shown in Bitex, but it has no effect on the transmitter operation. rcp8-9.0.0.12.gz --- posted 22-Jan-2021 Installation instructions: # cp rcp8-9.0.0.12.gz /usr/sigmet/bin # cd /usr/sigmet/bin # systemctl stop rcp8 # mv rcp8 rcp8-9.0.0 ( or if rcp8 patch 6 installed, then unlink it with command "unlink rcp8") # gunzip rcp8-9.0.0.12.gz # chown root.users rcp8-9.0.0.12 # chmod 6775 rcp8-9.0.0.12 # ln -s rcp8-9.0.0.12 rcp8 # chown -h root.users rcp8 # systemctl start rcp8 ================ IRIS/RDA patch 13 ================== Address the following: Alarm is not triggered anymore based on flowrate. A fault in the new Cibred dehydrator does not stop transmitter radiation. The alarm (e.g. low pressure) is shown in Bitex, but it has no effect on the transmitter operation. Triggering alarm with hard coded limits if the dehydrator itself fails to set alarm. Dehydrator is configured to alarm when pressure <30 or >50. Target pressure is 40. Hard coded limits are 20 and 70. rcp8-9.0.0.13.gz --- posted 28-Jan-2021 Installation instructions: # cp rcp8-9.0.0.13.gz /usr/sigmet/bin # cd /usr/sigmet/bin # systemctl stop rcp8 # mv rcp8 rcp8-9.0.0 ( or if rcp8 patch 6 installed, then unlink it with command "unlink rcp8") # gunzip rcp8-9.0.0.13.gz # chown root.users rcp8-9.0.0.13 # chmod 6775 rcp8-9.0.0.13 # ln -s rcp8-9.0.0.13 rcp8 # chown -h root.users rcp8 # systemctl start rcp8