Invoking Zauto
-
Run the Setup utility.
-
In the command line, type: zauto&
If needed, use one of the following options:
Option Description -burst_pwr-BW_is_invPWOptional parameters for the –caloption.-calPerforms an automatic calibration without displaying the zauto menu. The results are saved to the calibration file, unless there is a value outside the tolerance range. This option is available only with an automatic siggen. -debugUse this to debug Zauto. -demo-demo2Runs the utility without the signal processor, for testing and demonstration purposes. -pol H or VForces polarization to horizontal or vertical in Zauto startup. -pw_idx 1 - 4Select the pulse width index used for defining the pulse width for automatic calibration. -display display_name - For magnetron systems, when you are done with Zauto, recheck the frequency for drift.
