Logic Equation Configuration of Variables
Use these questions to configure the internal variables used within logic equations.
To access these questions, in the
RCP> prompt, type: Control Variables
Choose: Retrig Single Filter Retard Extend Clock
Timer #0 trigger mode: Retrig
Timer #0 period/delay: 1.0
There is a question in this form for each of the available timers. Choose the mode of each timer (See Logic Equation Timer Variables), and its associated period or delay (in seconds).
Minimum velocity for 'antstop': 0.50 deg/sec
Minimum time for 'antstop': 2.00 sec
The status variable antstop is set to:
-
TRUEwhen the antenna seems to be stopped, that is, has been moving slower than a prescribed speed for more than a prescribed time.These setup questions configure the speed and time thresholds.
Both the AZ and EL axes must appear to be stopped in order for antstop to be
TRUE. FALSEwhen the antenna seems to be moving, that is, the speed on either axis has exceeded the threshold speed for more than the specified time.