TTY Control Request Monitor
This display shows the control functions handled by RCP8.
To enter the control request monitor, in the Main menu, type: monitor control
The primary control functions that have been externally requested (usually from the host computer) are shown in the following display:
Requested Primary Control Bits
Pw1 Pw0 Rad Srv T/R Res IRIS
––– ––– ––– ––– ––– ––– ––––
ON 000
To view the qualified state of each control function, give the / sub-command. This shows the actual control state, which may be different from the requested state if any internal logic equations override the request. See Logic Equation Control Qualifiers.
Qualified Primary Control Bits
Pw1 Pw0 Rad Srv T/R Res IRIS
––– ––– ––– ––– ––– ––– ––––
ON ON 000
|
The / sub-command works as a toggle between the requested and qualified states of the shown control variables. This makes it easy to compare the bits, and to verify that custom logic equations are implemented correctly. |
Use the alt sub-command to switch to a display of requested auxiliary control bits:
Requested Auxiliary Control Bits
C[63:56] C[55:48] C[47:40] C[39:32] C[31:24] C[23:16] C[15:08] C[07:00]
........ ........ ........ ........ ........ 11...... 1....... ........
from which the / sub-command can switch to the qualified states:
Qualified Auxiliary Control Bits
C[63:56] C[55:48] C[47:40] C[39:32] C[31:24] C[23:16] C[15:08] C[07:00]
........ ........ ........ ........ ........ ........ 1....... ........
Use the following alt display to view timers and local logic variables:
Local Variables
V[15:08] V[07:00]
........ ........
Timers and Local Variables
T[15:8 ] T[ 7:0 ] V[31:24] V[23:16] V[15:8 ] V[ 7:0 ]
........ ........ ........ ........ ........ ........