RCP8 on Serial Interface

The RCP is connected through a serial line directly to the host computer. The following must be configured for this:

  • RCP TTY setups. See RCP8 User Guide (M212923EN)
  • Host computer setup/RCP configuration (for example, for IRIS)
setup/RCP
System has antenna ยจ
Main Interface to RCP Serial
Antenna angle insertion source Normal RCP
Is this the 1 controlling host Yes
Main serial device name /dev/ttyS1
Running at 19200
With parity None
Receive format from RCP RCV02
Transmit format to RCP XMT02

On RCP8 itself, set Setup > RCP set to:

setup/RCP
System has antenna Yes
Main Interface to RCP None
Antenna angle insertion source Native RCP8

For more information on setting-up a serial line interface, see RCP8 User Guide (M212923EN).

The AntExport utility may be run on the host computer to export control to another computer.