Klystron BITE Packets

Klystron BITE Packet (RCP8 to Host)
Char Function Status bit
1 SYNC (C0 Hex)
2 Identification byte (User choice)
3 Klystron status and fault conditions (Machine state)
D0 = Power On S134
D1 = Standby S135
D2 = Radiate S136
D3 = Fault Sum S137
D4 = Fault Latch S138
D5 = Reserved S139
D6 = Reserved S140
4 Klystron status and fault conditions (Faults)
D0 = HVPS Over Temp S141
D1 = Oil Level S142
D2 = Solenoid PS S143
D3 = HVPS Current S144
D4 = LVPS S145
D5 = HVPS (over cur/und volt) S146
D6 = Filament PS S147
5 Klystron status and fault conditions (Faults)
D0 = Ion Current S148
D1 = Klystron Current S149
D2 = Solenoid Current S150
D3 = Over Duty S151
D4 = Mod Over Temp S152
D5 = Disable radiate S153
D6 = Spare S154
6 Klystron status and fault conditions (Spare)
D0 = Klystron Connected S155
D1 = IGBT Fault #1 S156
D2 = IGBT Fault #2 S157
D3 = IGBT Fault #3 S158
D4 = IGBT Fault #4 S159
D5 = IGBT Fault #5 S160
D6 = IGBT Fault #6 S161
7 End of Message (FF Hex)
Klystron Q-BITE Packet (RCP8 to Host)
Char Function Klystron_status_c field
1 SYNC (AF Hex)
2 Identification byte (User choice)
3-4 Solenoid current fSolenoidCurrent (scale 100)
5-6 Klystron current fKlystronCurrent (scale 10)
7-8 Ion current fIonCurrent (scale 100)
9-10 Filament voltage fFilamentVoltage (scale 100)
11-12 Filament current fFilamentCurrent (scale 100)
13-14 Modulator current fModulatorCurrent (scale 100)
15-16 HVPS voltage iHVPSVoltage (scale 1000)
17-18 Peak cathode voltage fPeakCathodeVoltage (scale 100)
19-20 Peak cathode current fPeakCathodeCurrent (scale 1)
21 End of Message (FF Hex)