I/O connector panel
The RCP connector panel mounts on front or rear of standard 19 EIA rack and connects to I/O-62 via 1:1 62-pin 1.8 m (5 ft 11 in) cable (provided). It includes
- Three internal relays and 4 12 V relay control signals for switching external devices.
- Diagnostic power supply and self test LEDs for troubleshooting.
The connector panel uses programmable pin assignments made in softplane.conf and multiplexes the inputs and outputs of the I/O-62 PCI card.
| J-ID | Label | Type | Description |
|---|---|---|---|
| J1 | AZ INPUT |
DBF25 | 20 TTL lines configurable to be either input or output lines. Maximum input level allowed is TTL. |
| J2 | AZ OUTPUT |
DBF25 | 20 TTL lines configurable to be either input or output lines. Maximum input level allowed is TTL. |
| J3 | CONTROL |
DBF25 |
16 assignable digital control/status lines:
Two fixed RS422 differential lines. |
| J4 | EL INPUT |
DBF25 | 20 TTL lines configurable to be either input or output lines. Maximum input level allowed is TTL. |
| J5 | EL OUTPUT |
DBF25 | 20 TTL lines configurable to be either input or output lines. Maximum input level allowed is TTL. |
| J6 | RELAY |
DBF25 |
Three internal relays, contact rating 0.5 A continuous. The switching load is 0.25 A and 100 V, with the additional constraint that the total power not exceed 4 VA. Four 12 V relay control signals, up to 200 mA. Note that external relays should be equipped with proper diode protection to shunt the back EMF. |
| J7 | BITE 19:0 |
DBF25 | 20 TTL lines configurable to be either input or output lines. Maximum input level allowed is TTL. |
| J8 | ANALOG IN |
DBF25 | 10 differential analog inputs, up to ±20 V max multiplexed into A/D convertor sampling each at >1000 Hz. |
| J9 | PED/STATUS |
DBF25 |
AZ/EL tachometer differential inputs (±2 to ±70 VDC) and AZ/EL drive outputs (±10 VDC). 14 assignable digital control/status lines:
|
| J10 | SERIAL |
DBF9 | RS232C |
| J11 | SERIAL |
DBF9 | RS232C |
| J12 | S-D |
Modular | 3 × 4 matrix connector for AZ and EL synchro and reference inputs (nominally 90 V and 60 Hz). |
| J13 | TP1 |
BNC | Programmable scope test point. 75 Ω |
| J14/15 | SPARE |
BNC | |
| J16 | TP2 |
BNC | Programmable scope test point. 75 Ω |
| J17/18 | SPARE |
BNC |