Radar control and monitoring

Radar control and monitoring
Feature Description
Dedicated control outputs Servo power, Radiate, T/R power, Pulse width (4), Reset signal
Dedicated status inputs Servo power, Radiate, Standby, Waveguide pressure, Interlock, Cooling airflow, Pulse sidth (4), Antenna local mode
BITE inputs and outputs

Up to 100 TTL lines configurable in groups of 10 to either input or output lines.

100 additional lines can be added by adding a second I/O-62 card.

Other interfaces GPIB, CAN-bus, Ethernet
Radar status and control I/O
Feature Description
I/O configuration.

The I/O pin assignments to the connector panel are configured in softplane.conf.

This removes the need for jumpers and significantly reduces custom wiring.

Standard status inputs

Wide range inputs.

Standard parameters are Servo Power, Antenna Local Mode, Lower and Upper EL Limit switches, T/R power, T/R Local Mode, Radiate Standby, Radiate on, Magnetron Current, Wave Guide Pressure, Airflow, Interlock, external Reset input signal, Trigger Blanking input signal and pulse width (up to 4 coded in 2 bits).

Standard control outputs Wide range outputs or switch closures to ground. Standard parameters are Servo power, T/R power On/Off, Radiate On/Off (TTL or switch closure), Cabinet Relay, Trigger Blanking, equipment Reset signal, and pulse width (up to 4 bits).
Programmable control logic

User programmable status/control logic actions in a flexible C-like programming interface.

For example, if the antenna radome is opened, the system can automatically sound an alarm for a programmable time and immediately de-radiate and stop the antenna.