M+ Debug options

Noise level for simulated data

RVP10 debugging options help you develop and debug application code. You can also use these questions to put RVP10 in unusual operating states. These options are usually disabled during normal radar operation.

Noise level for simulated data: -50.0 dB

Limits: –100dB ... 0dB

This is the noise level that is assumed when simulated I and Q data is injected into RVP10 with the LSIMUL command. The noise level is measured relative to the power of a full–scale complex (I,Q) sinusoid, and matches the levels shown on the slide pots of the Ascope digital signal simulator.

Nyquist sign flip of plotted IF samples

Nyquist sign flip of plotted IF samples: NO

This question asks whether IF samples should be plotted with Nyquist flipping (multiplication by +1,–1,+1,–1...).

If YES, the Pr and Pb plots modify their rendering of IF samples. In those menus, the text (NyFlip) appears in the plot text heading when sample flipping is being applied. Other plots in these menus, such as spectra and LOG magnitude, are unaffected by the Nyquist flipping, nor are any live parameters derived from the IF samples. Only the visual appearance of the IF samples is affected.