Using the TTY setup menu
You can view and modify most RVP10 operating parameters with the TTY setup menu. For example:
-
Make TTY connections
-
Save and restore configurations
For example, you can configure custom trigger patterns, pulse width control, matched FIR filter specs, PRF, and so on, in the field.
-
Access graphical setup and monitoring procedures that use an ordinary oscilloscope as a synthesized visual display.
The burst pulse and receiver waveforms are displayed in the time and frequency domain.
The digital FIR filter matches the characteristics of the transmitted pulse.
-
To access the TTY menu:
- To view RVP and IRIS software versions, type V
- For a list of available commands, type help
-
To exit the menu and reload RVP10 with the changed set of current values, type:
Q
Settings are saved in a configuration file so they take immediate effect on start-up.
You must exit the menus using the Q before resuming normal RVP operation.
Portions of the RVP command interpreter continue to run while the menus are active, but the processor does not function until you exit the menus.
- To return to the Linux command prompt, press .