Vp – View processing and threshold values
The Vp command displays internal parameters that affect moment processing within RVP10. This information is for inspection only, and cannot be changed from the TTY.
The threshold parameters are LOG (receive power above noise), CSR, weather signal power (WSP), SQI, and Polarimetric Met Index (PMI). The threshold control flags (TCF) column shows numeric and symbolic forms.
Threshold Settings for All Data Parameters
LOG CSR WSP SQI PMI TCF (Equation)
--- --- --- --- --- -------------
DBZ: 0.75dB -18.0dB 5.0dB 0.149 0.449 0x8888( LOG& CSR )
DBT: 0.75dB -18.0dB 5.0dB 0.149 0.449 0xFFFF( AllPass )
VEL: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
WID: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xA000( LOG& SQI &SIG )
ZDR: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xAAAA( LOG )
KDP: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
PHIDP: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
RHOHV: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
SQI: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xFFFF( AllPass )
LDRH: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xAAAA( LOG)
RHOH: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
PHIH: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
LDRV: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xAAAA( LOG )
RHOV: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
PHIV: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
HCLASS: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xC0C0( CSR& SQI )
SNR: 0.75dB -18.0dB 5.0dB 0.398 0.449 0xFFFF( AllPass )
DBZA: 0.75dB -18.0dB 5.0dB 0.149 0.449 0x8888( LOG& CSR )
DBTA: 0.75dB -18.0dB 5.0dB 0.149 0.449 0xFFFF( AllPass )