Factory settings, saved settings, and current settings
RVP settings included:
- Current settings—Values with which RVP10 is currently operating.
- Saved settings—Values stored in a permanent configuration file. The saved settings are restored (made current) each time RVP10 starts.
RVP10 retains the saved settings when new software releases are installed. The new version of the code automatically uses all of the previous saved values. If RVP10 detects a new setup parameter, it is set to a factory default value and a warning is printed if this occurs. See V and Vz – View card and system status.
| Command | Description |
|---|---|
| S | Saves the current settings into the rvp10.conf configuration file. |
| R | Restores those non-volatile values so that they become the current settings. |
| F |
Initializes the current settings with factory default values of RVP10. The factory default values do not correspond to any user installation, and they are not meant to be applied in normal situations. |
| F S |
Saves factory defaults in non-volatile RAM. The site-specific power up settings are overwritten, irreversibly, and RVP10 powers up in its manufacturing mode. This is not recommended. |
| V |
Shows the currently running versions of RVP and IRIS software. |
|
You must exit the menus using the Q before resuming normal RVP operation. Portions of the RVP command interpreter continue to run while the menus are active, but the processor does not function until you exit the menus. |