Configuring RDA software

After the receiving your unit from the factory, or after software re–installation, you must configure the software to customize your system for your environment and application.

RDA configuration tools
Configuration tool RDA device Description

setup/RVP utility

setup_dsp.conf

See IRIS and RDA Utilities Guide (M211316EN).

RVP10

Configures the local environment required to run RVP support utilities such as Ascope and dspx.

Examples: radar equation parameters that are required for calibration, pulse width definitions, and PRF request limits.

setup/RCP utility

setup_ant.conf

See RVP10 User Guide (M212604EN).

RCP8

Configures the local environment required to run the RCP8 support utilities that such as Antenna or Bitex.

Examples: max allowed AZ/EL velocity request, MIN and MAX elevation angles that can be requested, and LAT/LON of radar for sun tracking.

RVP10 NV setups

rvp10.conf

See RVP10 User Guide (M212604EN).

RVP10

Defines the details of the sampling and processing algorithms, as well as the operational configuration of the system.

Examples: IF filter design and selection, PRF limits, relative trigger timing, dual-polarization features.

RCP8 NV setups

rcp8.conf

See RCP8 User Guide (M211320EN).

RCP8

Configures which status and control bits are available and define the antenna servo control parameters.

Examples: physical or virtual tachometer selection, shutdown safety criteria and internal antenna simulator on/off.

softplane.conf

RVP10

RCP8

Defines the I/O signals on the I/O-62 connector panel, pin-by-pin.

Examples: whether a line is an input or output, electrical specification such as RS422 or TTL, what local variable name is associated with each line.

note During installation, you must configure the Setup utility and the TTY setups for your system.

The configuration results are stored as ASCII text .conf files, typically in the /etc/vaisala/irisrda directory. Each file has a factory default configuration file that is stored in the template directory. The default is:

/etc/vaisala/irisrda/templates/init/
tip For a radar network with identical hardware, you can perform configuration maintenance by copying pre-tested files over the network.