Installing IO-62 firmware

If you have installed or upgraded the RDA software, and your system includes an IO-62 card and connector panel, you must update the firmware running on RCP8 to be compatible with the installed RDA software.

  1. Login as root
  2. Check for running processes by typing: ps-iris
  3. Stop any running processes by typing:
    # qiris
    # quant
  4. Log in as radarop (with password xxxxxx)

    You enter X–Windows.

  5. Right-click and start a terminal window.
  6. For each Vaisala component, type the appropriate command. For example:
    Vaisala component Command
    Standard I/O-62 card io62-0
    Standard connector panel io62cp-0
  7. Shut down the system by typing: poweroff
  8. When Power down is displayed, turn power off with power switch on lower right of front panel.

    The FPGA software installation is complete.

  9. Reboot the unit.

    Follow the progress of the reboot on the monitor. The front panel LED display shows the time of the reboot and display diagnostic messages.

    The reboot takes about 1 minute.

  10. Stop the RCP process by typing:
    $ killall rcp8
  11. Run the following diagnostics and observe the results:
    $ rdadiags io62–0 
     $ rdadiags io62cp-0 
  12. Restart the RCP8 process by typing:
    rcp8 &
  13. Verify that the restart messages show no faults.
  14. Configure RCP.

    See RCP8 User Guide (M211320EN).