RVP TTY Setups for dual-system support
In RVP, you must define whether to inhibit the trigger when its associated RCP is inactive. Whether or not this is necessary is determined by the radar manufacturer. Respond to the following questions in the mt (general trigger setup) section:
Blank output triggers according to TAG#0: YES
Blank when tag input is high: YES
Blank triggers 1:YES 2:YES 3:YES 4:YES 5:YES 6:YES
These questions control trigger blanking based
on the TAG0 input line. You first select whether the trigger blanking feature
is enabled; and then optionally choose the polarity of TAG0 that results in blanking
(consistent with RCP8 setups), and which subset of the 6 user-definable triggers are to be
blanked.
Note that for maintenance, RVP10 on the inactive system can be made to generate a trigger by any one of the following techniques:
- One of the 6 triggers can be set to
Blank triggers NO. This could be used to provide a permanent maintenance trigger. - Temporarily respond
Blank output .. TAG#0: NO - Install a physical override switch on one of RCP8 BITE inputs and then, using the control logic, enable the triggers.