Set burst pulse processing options (BPOPTS)

Use this command to set burst pulse processing options.

 15  14  13  12  11  10   9   8   7   6   5   4   3   2   1   0
 ---------------------------------------------------------------
|   |   |   |   |   |   |   |   |   |   |   |   |   |   |   |   |
|                 FILTER| 0   0   0   1    1   1  0   1   1   1 |  Command 
|-----------------------|---------------------------------------|  
 15  14  13  12  11  10   9   8   7   6   5   4   3   2   1   0
 ---------------------------------------------------------------
|   |   |   |   |   |   |   |   |    |   |   |   |   |   |   |   |
|                 FILTER                         |ACY|ACN|PLY|PLN|  Input 1 
|---------------|------------------------------------------------|  
PLY/N

Affects whether RVP10 phase locks its (I,Q) data to the measured burst pulse.

The PLY and PLN bits force Yes and No responses. If both bits are clear or both bits are set, no change is made.

ACY/N

Affects whether RVP10 applies pulse-to-pulse amplitude correction to its (I,Q) data.

The ACY and ACN bits force Yes and No responses. If both bits are clear or both bits are set, no change is made.