Set Individual Thresholds (THRESH)
The SOPRM command allows you to configure 4 threshold numbers used by all data types, and to select the threshold control flags for 5 of the data types. See Setup operating parameters (SOPRM).
Use the THRESH command if you wish to apply different threshold numbers to different data types. You can individually set the thresholds and mask used for each data type, or for groups of data types.
The GPARM command reads out the threshold numbers set for velocity. To read back the numbers for each data type use the RBACK command. See Read back internal tables and parameters (RBACK).
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| | 0 0 0 1 0 1 1 1 1 1 1 1 | Command
|---------------|------------------------------------------------|
The first 3 words supply a mask that indicates which data types are being set:
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| | Z | T | V | W |ZDR| |KDP | | Input 1
|---|---|---|---|---|---|-------|----|---------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| |Flg|Phi Rho Ldr|Phi Rho Ldr|SQI|RHV|PDP| Input 2
|-----------------------|---|---|----|---|---|---|---|---|---|---|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| <all spares> | Input 3
|---------------|------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| LOG Threshold in 1/16 of dB(SOPRM Input 4) | Input 4
|---|---|---|---|---|---|-------|----|---------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| CCOR Threshold in 1/16 of dB(SOPRM Input 5) | Input 5
|---|---|---|---|---|---|-------|----|---------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| SQI Threshold in 1/16 of dB(SOPRM Input 6) | Input 6
|---|---|---|---|---|---|-------|----|---------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Weather Signal Power Threshold in 1/16 of dB(SOPRM Input 7) | Input 7
|---|---|---|---|---|---|-------|----|---------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| Threshold Control Flags(SOPRM Input 11,12,13,14,19) | Input 8
|---|---|---|---|---|---|-------|----|---------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| <spare> | Input 9
|----------------------------------------------------------------|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
---------------------------------------------------------------
| | | | | | | | | | | | | | | | |
| <spare> | Input 10
|----------------------------------------------------------------|