task_calib_info Structure
Source: iris_task.h
| Byte | Size | Contents |
|---|---|---|
| 0 | SINT2 | Reflectivity slope (4096*dB/ A/D count) |
| 2 | SINT2 | Reflectivity noise threshold (1/16 dB above Noise) |
| 4 | SINT2 | Clutter Correction threshold (1/16 dB) |
| 6 | SINT2 | SQI threshold (0–1)*256 |
| 8 | SINT2 | Power threshold (1/16 dBZ) |
| 10 | 8 | <spare> |
| 18 | SINT2 | Calibration Reflectivity (1/16 dBZ at 1 km) |
| 20 | UINT2 | Threshold flags for uncorrected reflectivity |
| 22 | UINT2 | Threshold flags for corrected reflectivity |
| 24 | UINT2 | Threshold flags for velocity |
| 26 | UINT2 | Threshold flags for width |
| 28 | UINT2 | Threshold flags for ZDR |
| 30 | 6 | <spare> |
| 36 | UINT2 |
Flags: Bit 0: Speckle remover for log channel Bit 3: Speckle remover for linear channel Bit 4: Flag to indicate data is range normalized Bit 5: Flag to indicate pulse at beginning of ray Bit 6: Flag to indicate pulse at end of ray Bit 7: Vary number of pulses in dual PRF Bit 8: Use 3 lag processing in PP0 2 Bit 9: Apply velocity correction for ship motion Bit 10: Vc is unfolded Bit 11: Vc has fallspeed correction Bit 12: Zc has beam blockage correction Bit 13: Zc has Z-based attenuation correction Bit 14: Zc has target detection Bit 15: Vc has storm relative velocity correction |
| 38 | 2 | <spare> |
| 40 | SINT2 | LDR bias in signed 1/100 dB |
| 42 | SINT2 | ZDR bias in signed 1/16 dB |
| 44 | SINT2 | NEXRAD point clutter threshold in 1/100 of dB |
| 46 | UINT2 | NEXRAD point clutter bin skip in low 4 bits |
| 48 | SINT2 | I0 cal value, horizontal pol, in 1/100 dBm |
| 50 | SINT2 | I0 cal value, vertical pol, in 1/100 dBm |
| 52 | SINT2 | Noise at calibration, horizontal pol, in 1/100 dBm |
| 54 | SINT2 | Noise at calibration, vertical pol, in 1/100 dBm |
| 56 | SINT2 | Radar constant, horizontal pol, in 1/100 dB |
| 58 | SINT2 | Radar constant, vertical pol, in 1/100 dB |
| 60 | UINT2 | Receiver bandwidth in kHz |
| 62 | uint16_t |
Flags2: Bit 0: Zc and ZDRc has DP attenuation correction Bit 1: Z and ZDR has DP attenuation correction |
| 64 | 256 | <spare> |