This configures IRIS ingest clutter map. If the Task Configuration
Menu clutter map button is pressed, IRIS looks for a ingest file marked as
the residual clutter map. All range bins containing data in the clutter map file are
thresholded unless the current data is at least this much higher. If we exceed the
threshold, the dBZ value is passed unchanged.
Elevation tolerance for matchup
When looking for the corresponding range bin in the clutter map file, the nearest
elevation angle is used up to this maximum difference. If none is found, then no
correction is applied.
Non-zero velocity criterion
If this is set to Check Velocity then data which
would pass the excess power test is thresholded if the velocity is near 0.
Clutter map in ReINGEST
If this is set to Enabled, the
Clutter_map filter is applied to the data in reingest. The filter is
only applied if no other clutter map filter has been used. The ingest file from that radar
site must have the same task name and be marked as the clutter map.