Velocity Unfolding
- Maximum age of the "UNFOLD" VVP7
-
IRIS can be configured to automatically unfold velocity data, producing a data type called
Vcbased on aVVPproduct on the disk which must be calledUNFOLD.This is the maximum time difference between the data and the time of the
UNFOLDproduct.A 0 value disables the check.
See the
NDOPproduct in IRIS Product and Display Guide (M212928EN). - Maximum separation to the VVP
- The maximum distance between the radar location of the
VVPproduct and the data being unfolded. It might be necessary to unfold based on a different radar when one radar's data is imported. - Velocity unfolding in ReINGEST
-
If enabled,
Vcusing unfolding is computed at reingest time, overriding any previous values.The recommended setting is Disabled, if unfolding is required, specify it in the task configuration.