Bandwidth Filter Adjustment
Test Goal
Set the band width filter for each pulse width.
Test Equipment
KVM connected
Test Procedure
- Enter the TTY setups through
dspx. - Issue the Ps command and view the results on the display scope.
- Toggle the space bar to show both the spectrum of the burst pulse and the spectrum of the bandwidth filter response.
- Use the Z/z command to zoom the burst spectrum plot to approximately match the height of the bandwidth filter response (which have a smoother shape than the burst pulse).
- Use the Ww/Nn commands to adjust the width of the bandwidth filter
plot to be slightly narrower than the burst pulse. Then use the w/n
commands to fine tune the filter width such that the
DC–Gain:is eitherZEROor less than -66 dB. - Repeat for each pulse width that is used (use the Mt command to
change pulse width) and record:
Pulse width # FIRLength Bandwidth DC Gain 0 ________ μsec ________ MHz ________ dBm 1 ________ μsec ________ MHz ________ dBm 2 ________ μsec ________ MHz ________ dBm 3 ________ μsec ________ MHz ________ dBm
Checklist
| Task | Checked OK/Not OK | Remarks |
|---|---|---|
| Test procedure completed successfully. | ||
|
Parameters are set. |
||
| Test Passed | ||
| For Customer | Date: | |
| For Vaisala | Date: | |