MFC Functional Test and Tuning (Optional)
Test Goal
Verify that the Manual Frequency Control (MFC) is functioning properly.
| Skip this test if you are not using the RVP10 AFC. |
Test Equipment
KVM connected
Test Procedure
-
Enter the TTY setups through
dspx. -
Type the Ps command (Plot burst spectrum and AFC).
-
Type the = command to enter the MFC (manual frequency control) mode.
Verify that the MFC mode is indicated by the Manual notation next to the AFC % output indicator on the terminal.
-
Use the U/u and D/d commands and verify that these commands shift the measured IF frequency (as displayed on the TTY) either up or down.
The U command should increase the frequency and the D command should decrease the frequency. If the sense is reversed, go to the Mb command menu and change the question Burst frequency increases with increasing AFC voltage.
-
Using the U/u and D/d commands, verify the limits of the AFC tuning and fill in the following table:
AFC % Measured Frequency (MHz)
-100% ______ 0% ______ +100% ______ The 0% AFC value should be within approximately ±0.2 MHz of the center IF frequency (for example, 30 MHz).
The values at ±100% should correspond to approximately ± 7 MHz of the center IF frequency, or at the maximum span that is supported by the STALO; whichever is less.
- Toggle the MFC mode to AFC:
- Type: =
- Verify that the terminal indicator changes from Manual toAFC.
-
Exit the Ps menu.
Checklist
| Task | Checked OK/Not OK | Remarks |
|---|---|---|
| Test procedure completed successfully. | ||
|
Parameters are set. |
||
| Test Passed | ||
| For Customer | Date: | |
| For Vaisala | Date: | |