Test Goal
Verify that the IFDR10 TxDAC electrical I/O is working properly in an isolated environment.
Test Equipment
IRIS dspx utility
IF signal generator
Test Procedure
- Enter the TTY setups through
dspx. - Run
dspxand temporarily revert to factory settings with f. - In the Mb menu,
choose an intermediate frequency that matches the IFDR10 analog output filters (for
example, 60 MHz) and a Blackman
window.
Receiver Intermediate Frequency: 60.0000 MHz Design/Analysis Window– 0:Rect, 1:Hamming, 2:Blackman : 2 - Enter the Pr menu and type RRRTTZ to move the starting plot range to 30 km, the plot interval to 20 μsec, and zoom factor to x2.
- Type 2 space characters to switch to the spectral display plot and exit the plot by typing: q
-
In the Mz menu, setup the following:
Chan A – 0:Unused, 1:FixedFreq : 1, 2:TxWaveform: 1 FreeRunning fixed frequency : 60.00000 MHz Output power level : 0.0 dBm Apply pulse–to–pulse phase modulation: NO Fixed relative phase offset : 0.000 DegThe output frequency should match the IF previously set in Mb.
- Connect the IFDR10 TxDAC-A output to the ADC-A port of the IFD. It should be connected directly to the IFDR SMA input connector; not through any bandpass filter.
- Verify the plot shows a single strong spectral line at the selected Intermediate Frequency, and that any spurious signals are down at least 60 dB.
- Repeat the steps 5 to 8 on the TxDAC-B output port.
- Apply a 0 dBm SigGen waveform at the selected reference frequency (for example, 10 MHz) to the CLK IN BNC input of IFDR10.
- Verify the V command shows Tx/Clk:Okay, indicating the IFDR10 DAC is locking properly.
- Return to the center frequency and verify that lock returns.
Checklist
| Task | Checked OK/Not OK | Remarks |
|---|---|---|
|
Test procedure completed successfully. |
||
| Test Passed | ||
| For Customer | Date: | |
| For Vaisala | Date: | |